Kodak 8965758 Specifications Page 81

  • Download
  • Add to my manuals
  • Print
  • Page
    / 127
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 80
6 Operator Maintenance
Figure 6.8: Glass Flat Image
Dust or smudges on the glass flat can cause vertical streaks or make the image fuzzy;
therefore, the glass flat should be cleaned daily. Depending on use, it may be necessary
to clean the glass flat more frequently.
Note
When the scanner transport cover is open, a safety interlock removes power
from the transport motor before any hazardous parts are accessible.
To clean only the front side of the glass flat, perform the following:
1. Open the scanner transport cover, lifting it as high as it will rise.
2. Using the Optic Cleaning Pad, carefully clean the front surface of the glass. Inspect
the glass flat after cleaning to ensure all dust and residue has been removed.
3. Close the scanner transport cover.
6.4.1.1 Removing the Glass Flat
Caution
Do not twist or turn the glass flat while removing it so as not to damage it.
To remove the glass flat from the scanner, follow the procedure below:
1. Open the scanner transport cover.
2. Place your fingers on each end of the glass flat.
S006555 Rev D 67 of 113