Kodak i1200 User Manual

Browse online or download User Manual for Scanners Kodak i1200. Kodak i1200 User Manual [ru]

  • Download
  • Add to my manuals
  • Print
  • Page
    / 45
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
A-61560 January 2007 39
4 Image Processing
Overview This chapter introduces concepts that may be new to many users. The
Kodak i1200/i1300 Series Scanners provide the ability to process
scanned images to improve their quality. Using these features the
scanner can sometimes make the scanned image look better than the
original document. Basic image processing concepts are reviewed in
this chapter to help you take advantage of these features.
Image processing refers to several separate features of the scanner
that allow you to automatically adjust each image in a certain way that
may improve the resulting images. Common examples of image
processing features are correcting any skew in the fed document,
cutting the edges of the image off to remove any unneeded border or
cleaning up extraneous “noise” on the image. This can be done
automatically so you can get better images with a minimum amount of
rework.
The information that follows describes these image processing
features. The same options should be available on the user interface of
the scanning application you are using (i.e., Kodak Capture Software).
Starting the Scan
Validation Tool
1. Select Start>Programs>Kodak>Document Imaging>Scan
Validation Tool.
2. Select TWAIN (or ISIS) for the Driver Type and the Kodak Scanner
i12XX/i13XX Scanner as the Driver. The Scan Validation Tool
dialog box will be displayed.
Page view 0
1 2 3 4 5 6 ... 44 45

Summary of Contents

Page 1 - 4 Image Processing

A-61560 January 2007 394 Image Processing Overview This chapter introduces concepts that may be new to many users. The Kodak i1200/i1300 Series Scan

Page 2 - Scan Validation Tool

48 A-61560 January 2007 Move Up — moves the selected Setting Shortcut up one position in the Setting Shortcut list. When you move a Setting Shortcut,

Page 3 - Terminology and

A-61560 January 2007 49The Image Settings windowFrom this window you can define image processing options by using the available tabs. The values use

Page 4

50 A-61560 January 2007 Toolbar buttonsPreview area The main purpose of the preview area is to display a sample image that is based on your current sh

Page 5

A-61560 January 2007 51General tab The General tab contains the commonly used image options. In most cases, you will not have to change options on o

Page 6

52 A-61560 January 2007 Compression — allows you to reduce your electronic image size.• Type: the scanner will produce a color version of your documen

Page 7

A-61560 January 2007 53Size tab The Size tab allows you to define values relating to the image output (i.e., cropping values, paper size, etc.).Docu

Page 8 - Scanner window

54 A-61560 January 2007 Outline — allows you to select the location and size of your electronic image. The preview area will show the outline.• Origin

Page 9

A-61560 January 2007 55Post-scan rotation options — allows you to select any rotation to be applied to the electronic image after it has been scanne

Page 10

56 A-61560 January 2007 Adjustments tab: black and whiteThe options available on the Adjustments tab depend on the Scan as selection on the General ta

Page 11 - The Image Settings

A-61560 January 2007 57Threshold — aids in controlling the level at which a pixel is considered black or white. Decreasing this setting will make th

Page 12

40 A-61560 January 2007 Scan Validation Tool dialog boxThe Scan Validation Tool (SVT) is a diagnostic application provided by Kodak. The SVT user inte

Page 13

58 A-61560 January 2007 Adjustments tab: color or grayscaleThe options available on the Adjustments tab depend on the Scan as selection on the General

Page 14

A-61560 January 2007 59• Apply to: - Predominant - smooths the predominant background color to white.- Neutral - smooths only the neutral color to w

Page 15

60 A-61560 January 2007 Enhancements tab The options on the Enhancements tab depend on the Scan as selection on the General tab. Image Edge Fill — fil

Page 16

A-61560 January 2007 61Blank Image Detection — allows you to configure the scanner to not include blank images.• On: turns Blank Image Detection on

Page 17

62 A-61560 January 2007 Advanced Image SetupThe Advanced tab The Advanced Image Setup icon is located at the top of the Image Settings window next to

Page 18 - Adjustments tab: black

A-61560 January 2007 63Once you have done this, the Side drop-down list on the Image Settings window will no longer be grayed out and you can select

Page 19

64 A-61560 January 2007 Images to Configure — indicates which electronic images you need to configure.NOTE: This is only available if you select anyth

Page 20 - Adjustments tab: color

A-61560 January 2007 65Content Settings tab The options on the Content Settings tab can be used for either one- or two-sided jobs. Side — determine

Page 21

66 A-61560 January 2007 • Custom: allows you to manually adjust the Color amount and/or Color threshold.NOTE: When setting Sensitivity values, it is s

Page 22

A-61560 January 2007 67Creating color/grayscale or black and white images based on the content of your documents, Example 1In this example, let’s as

Page 23

A-61560 January 2007 41Save Images to Files — when selected, will save the images to the specified directory.Display Every  enter the sampling rate

Page 24 - Advanced Image

68 A-61560 January 2007 7. Go to the Content Settings tab. 8. Select a Sensitivity option.9. Select Done to return to the Image Settings window.NOTE:

Page 25

A-61560 January 2007 69Creating multiple images for each side of a document, Example 2In this example, let’s assume you want to configure a scan ses

Page 26

70 A-61560 January 2007 7. By default the scanner will produce the color/grayscale image first and deliver it to the scanning application, then it wil

Page 27

A-61560 January 2007 71Creating different settings for each side of a document, Example 3In this example, let’s assume you want to configure a two-s

Page 28

72 A-61560 January 2007 9. Select Black and White (1-bit) for the Scan as option on the General tab.NOTE: Make any other adjustments to the back side

Page 29

A-61560 January 2007 73Creating a new Setting Shortcut1. From the main Kodak Scanner window, select a Setting Shortcut from the list. It is recommen

Page 30

74 A-61560 January 2007 4. Select the appropriate options on the General tab.NOTE: If necessary, review each setting on the other tabs and make any ch

Page 31 - Creating multiple images

A-61560 January 2007 75Changing Image Settings1. Select a Setting Shortcut from the main Kodak Scanner window that closely describes your desired ou

Page 32

76 A-61560 January 2007 The Device Settings windowFrom this window you can set all scanner-specific options, as well as diagnostics, by using the avai

Page 33 - Creating different

A-61560 January 2007 77Device - General tab The General tab allows you to set scanner-specific transport control options.Paper Source • Automatic: l

Page 34

42 A-61560 January 2007 How do I begin? The goal is to make scanning as simple as possible. This is accomplished by selecting a Setting Shortcut from

Page 35 - Setting Shortcut

78 A-61560 January 2007 Device - Multifeed tab Multifeed detection aids in document processing by detecting documents that may go through the feeder o

Page 36

A-61560 January 2007 79Action When Detected — select what action you want the scanner to take when a multifeed is detected. With all options, the co

Page 37 - Settings

80 A-61560 January 2007 Changing Device settings1. Select a Setting Shortcut from the main Kodak Scanner window that closely describes your desired ou

Page 38 - The Device Settings

A-61560 January 2007 81The Diagnostics windowFrom this window you can access the diagnostic functions of the scanner. The Diagnostics window include

Page 39

82 A-61560 January 2007 Diagnostics - Debug tab The Debug tab allows you to store the communications between the scanner and a scanning application to

Page 40

A-61560 January 2007 83Images - Sent To Application • Save: click this checkbox to save final images from the scanner (after image processing is app

Page 41

A-61560 January 2007 43 Selecting Image settings From the main Kodak Scanner window: 1. Select a predefined Setting Shortcut from the Setting Shortc

Page 42 - Changing Device

44 A-61560 January 2007 5. If you are satisfied with your selected image processing options, reload your document if necessary and click OK/Scan.• If

Page 43 - The Diagnostics

A-61560 January 2007 45Selecting Device settings 1. Select the Setting Shortcut that you just created. 2. Select Settings to access the Image Settin

Page 44

46 A-61560 January 2007 The main Kodak Scanner windowThe main Kodak Scanner window is the home window of the scanner’s user interface. You can scan by

Page 45

A-61560 January 2007 47• If you have made changes to a Setting Shortcut and have not saved your changes, the Setting Shortcut will be appended with

Comments to this Manuals

No comments